Mouse Rantes PicoKine® Quick ELISA Kit (90 minutes, 96 Tests). Quantitate Mouse Ccl5 in cell culture supeatants. serum and plasma (heparin, EDTA, citrate). Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Immunogen
Expression system for standard: E.coli; Immunogen sequence: S24-S91
Kit Components
Description Quantity Volume Anti-tag Pre-coated 96-well Strip Microplate 1 12 strips of 8 wells Standard 2 Antibody A 1 3ml Antibody B 1 3ml Sample Diluent 1 15ml TBS-T Wash Buffer (25x) 1 12ml Color Developing Reagent (TMB) 1 10ml Stop Solution 1 10ml Adhesive Plate Sealers 2 Piece
Cross Reactivity
There is no detectable cross-reactivity with other relevant proteins.
Specificity
Natural and recombinant Mouse Ccl5
Sample Type
Cell culture supeatants, Serum, Plasma
Anticoagulant
heparin, EDTA or citrate
Precision
Intra-Assay Precision
Inter-Assay Precision
Sample
1
2
3
1
2
3
n
16
16
16
24
24
24
Mean (pg/ml)
27
186
435
22
185
429
Standard deviation
1.49
8.37
26.54
1.14
11.66
28.74
CV (%)
5.5%
4.5%
6.1%
6.4%
6.3%
6.7%
Background
Rantes (regulated on activation normal T cell expressed and secreted) is one of the natural ligands for the chemokine receptor CCR5 and potently suppresses in vitro replication of the R5 strains of HIV-1, which use CCR5 as a coreceptor. Peripheral blood mononuclear cells or CD4 (+) lymphocytes obtained from different individuals have wide variations in their ability to secrete RANTES. The Rantes gene product is predicted to be 10 kDa and, after cleavage of the signal peptide, approximately 8 kDa. Of the 68 residues, 4 are cysteines, and there are no sites for N-linked glycosylation. Rantes is expressed by cultured T cell lines that are Ag specific and growth factor dependent.
Reproducibility
Lots
Lot 1 (pg/ml)
Lot 2 (pg/ml)
Lot 3 (pg/ml)
Lot 4 (pg/ml)
Mean (pg/ml)
Standard Deviation
CV (%)
Sample 1
27
33
29
29
30
1.59
5.4%
Sample 2
186
181
188
168
181
11.03
6.1%
Sample 3
435
453
465
486
460
25.75
5.6%
*number of samples for each test n=16.
Notes
Material Required But Not Provided: Microplate Reader capable of reading absorbance at 450nm. Automated plate washer Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution. Horizontal orbital microplate shaker capable of maintaining a speed of 500 rpm, amplitude 3mm.