Human Rage PicoKine® Quick ELISA Kit (90 minutes, 96 Tests). Quantitate Human AGER in cell culture supeatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 10pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Alternative Names
cDNA FLJ56412, highly similar to Advanced glycosylation end product-specific receptor ;
Molecular Weight
45980 MW
Immunogen
Expression system for standard: NS0; Immunogen sequence: Q24-A344
Kit Components
Description Quantity Volume Anti-tag Pre-coated 96-well Strip Microplate 1 12 strips of 8 wells Standard 2 Antibody A 1 3ml Antibody B 1 3ml Sample Diluent 1 15ml TBS-T Wash Buffer (25x) 1 12ml Color Developing Reagent (TMB) 1 10ml Stop Solution 1 10ml Adhesive Plate Sealers 2 Piece
Cross Reactivity
There is no detectable cross-reactivity with other relevant proteins.
RAGE, the Receptor for Advanced Glycation Endproducts, is a 35kD transmembrane receptor of the immunoglobulin super family. It is also known as AGER. AGER gene is mapped to chromosome 6p21.3 by mapping by contiguous cosmids and YAC clones and by fluorescence in situ hybridization. The expression of RAGE is particularly increased in neurons close to deposits of amyloid beta peptide and to neurofibrillary tangles. RAGE has been linked to several chronic diseases, which are thought to result from vascular damage. The pathogenesis is hypothesized to include ligand binding upon which RAGE signals activation of the nuclear factor kappa B (NF-kappaB).
Reproducibility
Lots
Lot 1 (pg/ml)
Lot 2 (pg/ml)
Lot 3 (pg/ml)
Lot 4 (pg/ml)
Mean (pg/ml)
Standard Deviation
CV (%)
Sample 1
154
153
141
152
150
5.24
3.4%
Sample 2
623
570
627
596
604
22.96
3.8%
Sample 3
3076
3035
3093
3144
3087
39.08
1.2%
*number of samples for each test n=16.
Notes
Material Required But Not Provided: Microplate Reader capable of reading absorbance at 450nm. Automated plate washer Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution. Horizontal orbital microplate shaker capable of maintaining a speed of 500 rpm, amplitude 3mm.
Gene ID
177
Gene Name
AGER
UniProt ID
B4DNX3
Protein Name
Advanced glycosylation end product-specific receptor
Applications
ELISA
Storage
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)