Human CXCL10/IP-10 PicoKine® Quick ELISA Kit (90 minutes, 96 Tests). Quantitate Human CXCL10 in cell culture supeatants, serum, plasma (heparin, EDTA), saliva and urine. Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Immunogen
Expression system for standard: E.coli; Immunogen sequence: V22-P98
Kit Components
Description Quantity Volume Anti-tag Pre-coated 96-well Strip Microplate 1 12 strips of 8 wells Standard 2 Antibody A 1 3ml Antibody B 1 3ml Sample Diluent 1 15ml TBS-T Wash Buffer (25x) 1 12ml Color Developing Reagent (TMB) 1 10ml Stop Solution 1 10ml Adhesive Plate Sealers 2 Piece
Cross Reactivity
There is no detectable cross-reactivity with other relevant proteins.
Chemokine (C-X-C motif) ligand 10 (CXCL10) or IP-10 is a small cytokine belonging to the CXC chemokine family that is also known as 10 kDa interferon-gamma-induced protein (gamma-IP10 or IP-10). CXCL10 is secreted by several cell types in response to IFN-gamma. These cell types include monocytes, endothelial cells and fibroblasts. CXCL10 has been attributed to several roles, such as chemoattraction for monocytes/macrophages, T cells, NK cells, and dendritic cells, promotion of T cell adhesion to endothelial cells, antitumor activity, and inhibition of bone marrow colony formation and angiogenesis.It is a potent inhibitor of angiogenesis in vivo. The gene for CXCL10 is located on human chromosome 4 in a cluster among several other CXC chemokines. It is a RAS target gene and is overexpressed in the majority of colorectal cancers.This chemokine elicits its effects by binding to the cell surface chemokine receptor CXCR3.
Reproducibility
Lots
Lot 1 (pg/ml)
Lot 2 (pg/ml)
Lot 3 (pg/ml)
Lot 4 (pg/ml)
Mean (pg/ml)
Standard Deviation
CV (%)
Sample 1
66
55
61
58
60
3.54
5.9%
Sample 2
245
263
269
254
258
7.22
2.8%
Sample 3
894
935
842
971
911
49.17
5.4%
*number of samples for each test n=16.
Notes
Material Required But Not Provided: Microplate Reader capable of reading absorbance at 450nm. Automated plate washer Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution. Horizontal orbital microplate shaker capable of maintaining a speed of 500 rpm, amplitude 3mm.