Human A2M/Alpha2-Macroglobulin PicoKine® Quick ELISA Kit (90 minutes, 96 Tests). Quantitate Human A2M in cell culture supeatants, cell lysates, serum and plasma (heparin, EDTA). Sensitivity: 20pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Immunogen
Target protein isolated from human plasma
Kit Components
Description Quantity Volume Anti-tag Pre-coated 96-well Strip Microplate 1 12 strips of 8 wells Standard 2 Antibody A 1 3ml Antibody B 1 3ml Sample Diluent 1 15ml TBS-T Wash Buffer (25x) 1 12ml Color Developing Reagent (TMB) 1 10ml Stop Solution 1 10ml Adhesive Plate Sealers 2 Piece
Cross Reactivity
There is no detectable cross-reactivity with other relevant proteins.
Alpha-2-macroglobulin, also known as A2M or CPAMD5 is a large plasma protein found in the blood. This gene is mapped to 12p13.31. Alpha-2-macroglobulin is a protease inhibitor and cytokine transporter. It inhibits many proteases, including trypsin, thrombin and collagenase. A2M is implicated in Alzheimer disease (AD) due to its ability to mediate the clearance and degradation of A-beta, the major component of beta-amyloid deposits. This gene is able to inhibit all four classes of proteinases by a unique 'trapping' mechanism. This protein has a peptide stretch, called the 'bait region' which contains specific cleavage sites for different proteinases. When a proteinase cleaves the bait region, a conformational change is induced in the protein which traps the proteinase. The entrapped enzyme remains active against low molecular weight substrates (activity against high molecular weight substrates is greatly reduced). Following cleavage in the bait region a thioester bond is hydrolyzed and mediates the covalent binding of the protein to the proteinase.
Reproducibility
Lots
Lot 1 (pg/ml)
Lot 2 (pg/ml)
Lot 3 (pg/ml)
Lot 4 (pg/ml)
Mean (pg/ml)
Standard Deviation
CV (%)
Sample 1
1336
1254
1452
1396
1360
61.18
4.5%
Sample 2
3774
3674
3364
3354
3542
254.99
7.2%
Sample 3
26412
33012
29451
29456
29583
1804.55
6.1%
*number of samples for each test n=16.
Notes
Material Required But Not Provided: Microplate Reader capable of reading absorbance at 450nm. Automated plate washer Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution. Horizontal orbital microplate shaker capable of maintaining a speed of 500 rpm, amplitude 3mm.