Matrices listed below were spiked with certain level of Adh1 and the recovery rates were calculated by comparing the measured value to the expected amount of Adh1 in samples.
Matrix
Recovery range(%)
Average(%)
serum(n=5)
91-105
98
EDTA plasma(n=5)
90-100
95
heparin plasma(n=5)
90-104
99
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Adh1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Adh1/Adh-1/Alcohol dehydrogenase A subunit/Alcohol dehydrogenase 1
Notes
For Research Use Only
UniProt ID
P06757
Antigen
ADH1
Applications
ELISA
Applications Notes
Adh1 ELISA Kit allows for the in vitro quantitative determination of Adh1 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Precision
Intra-Assay: CV<8% Inter-Assay: CV<10%
Storage
2-8 °C for 6 months