This kit is based on indirect ELISA detection method and takes 3h assay time. The microplate provided in this kit has been precoated with antigen. HRP-antibody is used as detection antibody. Add standard and properly diluted sample into relevant well respectively. After incubation, wash unbound components. Add HRP-detection antibody, then it binds with anti-2019 nCoV (S) IgA bound to precoated antibody. Wash unbound components and add TMB substrate solution. Then, TMB was catalyzed by HRP to produce a blue color product that turned yellow after adding a stop solution. Read the O.D. absorbance at 450nm in a microplate reader. Calculate the concentration of anti-2019 nCoV (S) IgA in the sample by plotting standard curve. The concentration of the target substance is proportional to the OD450 value.
Alternative Names
SARS-CoV-2(S)IgA ELISA Kit
Recovery
Add a certain amount of anti-2019 nCoV (S) IgA into the sample. Calculate the recovery by comparing the measured value with the expected amount of anti-2019 nCoV (S) IgA in the sample.
Sample Type
Recovery Range(%)
Average(%)
serum(n=10)
85-98
96
EDTA plasma(n=10)
90-105
94
Heparin plasma(n=10)
86-104
96
Linearity
Dilute the sample with a certain amount of anti-2019 nCoV (S) IgA at 1:2, 1:4 and 1:8 to get the recovery range.
Sample Type
1:2
1:4
1:8
serum(n=10)
85-105%
85-97%
80-99%
EDTA plasma(n=10)
88-103%
82-93%
88-99%
Heparin plasma(n=10)
88-104%
82-100%
88-95%
Specificity
Specifically binds with anti-2019 nCoV (S) IgA , no obvious cross reaction with other analogues.
Standard Curve
This product is detected by QC department and meets performance required in the manual. (Laboratory Humidity: 20%-60%; Temperature: 18°C -25°C; Equilibrate TMB substrate to 37°C before staining. After adding into the ELISA wells, incubate for 15min at 37°C in dark.) Due to different assay environments and operations, assay data below and standard curve are provided for reference. Experimenters should establish standard curve according to their own assay.
Intra-assay Precision: samples with low, medium and high concentration are tested 20 times on the same plate. Inter-assay Precision: samples with low, medium and high concentration are tested 20 times on three different plates.
Item
Intra-assay Precision
Inter-assay Precision
Sample
1
2
3
1
2
3
n
20
20
20
20
20
20
Mean (ng/ml)
0.32
1.24
5.18
0.33
1.18
5.09
Standard deviation
0.02
0.07
0.24
0.02
0.06
0.25
CV(%)
5.91
5.26
4.68
4.93
5.22
4.89
Stability
Perform the stability test for the sealed kit at 37°C and 2-8°C and get relevant data.
ELISA kit(n=5)
37°C for 1 month
2-8°C for 6 months
Average(%)
80
95-100
Notes
For Research Use Only
Usage Notes
Step 1: Take out the required plate wells, add 50ul Cap/Det Ab into each well, then add 50ul Standard or Sample into individual well. (When adding standard or sample, the disposable tip lightly touches the liquid level. Change the disposable tips for different samples and standards.) Gently tap the plate for 10s to ensure thorough mixing then static incubate for 60 minutes at 37°C.
Washing: Wash the plate twice without immersion.
Step 2: Add 100ul HRP-Streptavidin (orange) into each well, seal the plate and static incubate for 30 minutes at 37°C.
Washing: Wash the plate five times without immersion.
Step 3: Add 90ul TMB substrate solution, seal the plate and static incubate for 10-20 minutes at 37°C. (Accurate TMB visualization control is required.)
Step 4: Add 50ul stop solution. Read at 450nm immediately and calculate.
Antigen
SARS-CoV-2 S
Applications
ELISA
Applications Notes
Anti-2019 nCoVIgA ELISA Kit allows for the in vitro quantitative determination of Anti-2019 nCoV(S)IgA concentrations in serum, plasma, tissue homogenates and other biological fluids.