Human VEGF PicoKine® Quick ELISA Kit (90 minutes, 96 Tests). Quantitate Human VEGFA in cell culture supeatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 1pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Immunogen
Expression system for standard: NS0; Immunogen sequence: A27-R191
Kit Components
Description Quantity Volume Anti-tag Pre-coated 96-well Strip Microplate 1 12 strips of 8 wells Standard 2 Antibody A 1 3ml Antibody B 1 3ml Sample Diluent 1 15ml TBS-T Wash Buffer (25x) 1 12ml Color Developing Reagent (TMB) 1 10ml Stop Solution 1 10ml Adhesive Plate Sealers 2 Piece
Cross Reactivity
There is no detectable cross-reactivity with other relevant proteins.
Specificity
Natural and recombinant Human VEGFA
Sample Type
Cell culture supeatants, Serum, Plasma
Anticoagulant
heparin, EDTA or citrate
Precision
Intra-Assay Precision
Inter-Assay Precision
Sample
1
2
3
1
2
3
n
16
16
16
24
24
24
Mean (pg/ml)
77
280
953
72
263
988
Standard deviation
7.32
21.84
89.58
5.54
24.72
73.11
CV (%)
9.5%
7.8%
9.4%
7.7%
9.4%
7.4%
Background
Vascular permeability factor/vascular endothelial growth factor (VPF/VEGF), a potent cytokine expressed by most malignant tumors, has critical roles in vasculogenesis and both physiological and pathological angiogenesis.VEGF produced by tumor cells potently stimulates endothelial cell proliferation and angiogenesis and plays a key role in the pathophysiology of several neoplasias. VEGF may also play a pivotal role in mediating the development and progression of diabetic retinopathy.VEGF, a major regulator of angiogenesis, binds to two receptor tyrosine kinases, KDR/Flk-1 and Flt-1. The VEGF gene is mapped by fluorescence in situ hybridization to chromosome 6p12.
Reproducibility
Lots
Lot 1 (pg/ml)
Lot 2 (pg/ml)
Lot 3 (pg/ml)
Lot 4 (pg/ml)
Mean (pg/ml)
Standard Deviation
CV (%)
Sample 1
77
81
85
82
81
4.96
6.1%
Sample 2
280
266
264
251
265
11.94
4.5%
Sample 3
953
890
963
998
951
52.31
5.5%
*number of samples for each test n=16.
Notes
Material Required But Not Provided: Microplate Reader capable of reading absorbance at 450nm. Automated plate washer Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution. Horizontal orbital microplate shaker capable of maintaining a speed of 500 rpm, amplitude 3mm.