Human LILRB5/CD85c/LIR-8 ELISA Kit PicoKine® (96 Tests). Quantitate Human LILRB5 in cell culture supeatants, serum and plasma (heparin, EDTA, citrate). Sensitivity: 15pg/ml. The brand Picokine indicates this is a premium quality ELISA kit. Each Picokine kit delivers precise quantification, high sensitivity, and excellent reproducibility. Only our most reliable and effective kits qualify as Picokine, guaranteeing top-tier results for your assays.
Immunogen
Expression system for standard: NS0; Immunogen sequence: G24-G458
There is no detectable cross-reactivity with other relevant proteins.
Specificity
Natural and recombinant human LILRB5
Sample Type
Cell culture supeatants, Serum, Plasma
Anticoagulant
heparin, EDTA or citrate
Precision
Intra-Assay Precision
Inter-Assay Precision
Sample
1
2
3
1
2
3
n
16
16
16
24
24
24
Mean (pg/ml)
316
1622
4807
329
1719
5032
Standard deviation
18.33
72.99
293.23
25.33
147.83
367.34
CV (%)
5.8%
4.5%
6.1%
7.7%
8.6%
7.3%
Background
This gene is a member of the leukocyte immunoglobulin-like receptor (LIR) family, which is found in a gene cluster at chromosomal region 19q13.4. The encoded protein belongs to the subfamily B class of LIR receptors which contain two or four extracellular immunoglobulin domains, a transmembrane domain, and two to four cytoplasmic immunoreceptor tyrosine-based inhibitory motifs (ITIMs). Several other LIR subfamily B receptors are expressed on immune cells where they bind to MHC class I molecules on antigen-presenting cells and inhibit stimulation of an immune response. Multiple transcript variants encoding different isoforms have been found for this gene.
Reproducibility
Lots
Lot 1 (pg/ml)
Lot 2 (pg/ml)
Lot 3 (pg/ml)
Lot 4 (pg/ml)
Mean (pg/ml)
Standard Deviation
CV (%)
Sample 1
316
297
305
322
310
19.22
5.2%
Sample 2
1622
1529
1646
1531
1582
96.50
6.1%
Sample 3
4807
4976
4716
4921
4855
398.11
8.2%
*number of samples for each test n=16.
Notes
Material Required But Not Provided: Microplate Reader capable of reading absorbance at 450nm. Incubator. Automated plate washer . Pipettes and pipette tips capable of precisely dispensing 0.5 µl through 1 ml volumes of aqueous solutions. Multichannel pipettes are recommended for large amount of samples. Deionized or distilled water. 500ml graduated cylinders. Test tubes for dilution.
Gene ID
10990
Gene Name
LILRB5
UniProt ID
O75023
Applications
ELISA
Storage
Store at 4°C for 6 months, at -20°C for 12 months. Avoid multiple freeze-thaw cycles (Ships with gel ice, can store for up to 3 days in room temperature. Freeze upon receiving.)
Reviews of Human LILRB5/CD85c/LIR-8 ELISA Kit PicoKine®